Membrane Disc Fine‑Bubble Aerator

Membrane disc fine‑bubble aerators are high‑efficiency aeration components. Microslits across the elastic membrane generate fine, evenly distributed bubbles to deliver excellent oxygen transfer, low power draw and consistent aeration output.

They are widely used in municipal wastewater treatment plants, biochemical tanks, aeration basins, oxidation ditches, MBR systems, plus industrial wastewater projects for chemical, food, pharmaceutical and electroplating sectors.

Product Models

Model CategoryConstruction StyleDimension (mm)Membrane MaterialConnection TypeTypical Application
Screw‑in Disc AeratorThreaded connectionΦ215 / Φ260 / Φ300EPDM, Silicone, NBRG3/4, G1, NPTMunicipal sewage, biochemical tanks, oxidation ditches
Snap‑in Disc AeratorProng‑snap clip‑onΦ215 / Φ260 / Φ300EPDM, Silicone, NBRClip‑onTank retrofits, intermittently operated basins
Dome‑Shaped Disc AeratorAnti‑clogging dome geometryΦ215 / Φ260 / Φ300EPDM, Silicone, NBRThreadedHigh‑strength wastewater, variable‑quality process tanks
Single‑Orifice Disc AeratorSingle‑orifice fine‑bubble structureCustom sizesEPDMPush‑in connectionBiofilters, ceramsite media filter tanks
Retractable Lifting‑type Disc AeratorLift‑out serviceable designΦ215 / Φ260 / Φ300EPDM, Silicone, NBRQuick‑connectHigh‑maintenance aeration basins, retrofit projects

Core Features

  • Fine & Uniform Bubbles with High Oxygen‑transfer Efficiency

Small‑diameter bubbles create large gas‑liquid interfacial area for homogeneous diffusion and superior oxygenation performance.

  • Anti‑clogging & Back‑flow‑resistant Construction

Dome‑shaped profile plus top sealing gasket effectively prevents sludge back‑flow and pore blockage.

  • Tear‑resistant Long‑service‑life Membrane

Dome‑form rubber membrane distributes stress evenly, reduces fatigue deformation and minimises tearing risk.

  • Corrosion & Ageing Resistance

Membrane options: EPDM, silicone, NBR. Support base manufactured from high‑grade engineering plastic.

  • Intermittent‑operation Compatibility

Suitable for cyclic aeration cycles; sludge build‑up across membrane surfaces is kept low.

Performance Specifications

ItemSpecification
Disc DiameterΦ215 / Φ260 / Φ300
Overall Oxygen Mass‑transfer Coefficientkla(20℃) 0.204‑0.337 min⁻¹
Oxygenation Capacity0.112‑0.185 KgO₂/m³·h
Effective Service Area0.25‑1.0 m² per unit (subject to size)
Air Flow Rate1.5‑3.0 m³/h
Average Pore Size80‑100 μm
Aeration Head Loss180‑280 mmH₂O
Oxygen Utilisation Efficiency (3.2 m water depth)18.4‑27.7 %
Standard Aeration Efficiency4.46‑5.19 KgO₂/kWh
Membrane MaterialEPDM, Silicone, NBR (domestic / imported grades)
Mounting Height200‑270 mm above tank floor

Product Advantages

  • Energy‑saving & High‑efficiency:Up to 40 % energy savings compared with conventional aerators
  • Uniform Air Distribution:High‑density microslits deliver even bubble dispersion
  • Reliable Continuous & Cyclic Operation:Works steadily for both continuous and intermittent aeration modes
  • Service‑friendly Design:Retractable‑lift variant enables convenient inspection and maintenance
  • 适应性强:Broad Application Compatibility

Selection Guide

Selection FactorAvailable OptionsDescriptionRecommended Use‑case
Membrane MaterialEPDMCost‑effective for municipal applications, excellent anti‑ageing performanceMunicipal sewage, biochemical tanks, oxidation ditches
SiliconeHigh elasticity, good low‑temperature toleranceCold‑climate installations, low‑temperature process systems
NBROil‑resistant and chemically stable for industrial effluentsChemical, pharmaceutical, electroplating & food‑industry wastewater
Construction StyleThreaded screw‑inSecure sealing, straightforward installationNew‑build aeration tanks, standard basin geometries
Snap‑in clip‑onQuick clip assembly, ideal for retrofitsTank retrofits, intermittently‑run aeration basins
Dome‑shapedAnti‑clogging & anti‑back‑flow, finer bubble outputHigh‑strength wastewater, challenging variable‑quality tanks
Application ScenarioBiochemical / Aeration BasinsMain‑stream process, high oxygen‑transfer ratesMunicipal wastewater treatment plants
Filter / Ceramsite‑media TanksSingle‑orifice aerator delivers even bubble spreadBiofilters, MBR systems
Deep‑basin / High‑air‑volume SystemsCan be combined with tube aeratorsIndustrial‑wastewater, high‑loading biological processes

FAQ

Q:What service life can I expect from membrane disc fine‑bubble aerators?
A:Typical service life for EPDM membranes is 3‑5 years. Silicone and NBR membranes achieve 5‑8 years under normal operating conditions.
Regular inspection of membrane elasticity and slit condition helps extend overall system lifespan.

Q:Are these aerators prone to clogging?
A:The dome‑shaped geometry together with angled slit openings prevents sludge back‑flow and blockage.
Stable aeration performance is maintained even under intermittent cycles or high‑strength wastewater loading.

Q:Which treatment processes are compatible with these aerators?
A:Suitable for A/O, A²/O, SBR, oxidation ditch, MBR and other mainstream municipal wastewater workflows.
Also applicable for aeration and oxidation‑reaction systems for industrial effluents.

Q:How do I select the right membrane material?
A:EPDM — municipal and general‑purpose wastewater
Silicone — low‑temperature environments or high‑elasticity requirements
NBR — oil‑bearing and chemical‑rich industrial wastewater

Q:What is the suggested installation height?
A:Recommended mounting height: 200‑270 mm above tank floor. Around 200 mm for push‑flow set‑ups; adjust according to tank geometry and airflow demand.

Q:How should the aeration piping network be arranged?
A:Air manifolds should be laid out in a ring‑loop configuration for balanced pressure distribution.
Main pipe velocity: 10‑15 m/s; branch pipe velocity: 5 m/s.
Isolation valves shall be fitted for each aeration bank to enable airflow regulation.

Q:What oxygen‑transfer performance can be achieved?
A:At 3.2 m submergence depth, oxygen utilisation reaches 18.4‑27.7 % with standard aeration efficiency of 4.46‑5.19 KgO₂/kWh.
Energy savings of roughly 40 % versus older perforated‑pipe or coarse‑bubble aerators.

Q:Do these aerators support intermittent aeration cycles?
A:Yes. Self‑closing membrane slits inhibit water back‑flow, making them suitable for periodic / cyclic aeration operation.

Q:Can custom connection or mounting configurations be supplied?
A:Yes. Multiple thread standards including G3/4, G1 and NPT are supported; threaded, snap‑clip and quick‑connect mounting styles are available.

Q:What is the recommended maintenance interval?
A:Inspect membrane elasticity and slit condition every 6‑12 months. Clean or replace membranes if uneven bubbling or rising head‑loss is observed.

Q:What are the energy‑saving benefits?
A:Delivers 30‑40 % lower energy consumption compared with legacy aerators, with up to 40 % higher treatment capacity at equal airflow.
Well‑suited for energy‑saving retrofit projects and high‑efficiency biological systems.

Need Custom‑Tailored Solutions?

We provide technical support, product selection guidance and fast quotation services.