Flat‑Sheet MBR Membrane System

The flat‑sheet MBR membrane system consists of individual flat‑sheet membrane elements and modular UPVC membrane cassettes. It is purpose‑built for feed water with high contaminant and high suspended‑solid loads.

Constructed with high‑strength PVDF flat‑sheet membranes, this system delivers outstanding fouling resistance, robust structural stability, simple maintenance and dependable performance. It is widely deployed for printing‑dyeing wastewater, chemical process water, surface‑treatment effluent, industrial‑park sewage and large‑scale water‑reuse facilities.

Performance Parameters

ItemFlat‑Sheet Membrane ElementFlat‑Sheet Membrane Cassette (UPVC)
Membrane MaterialPVDFPVDF
Frame Material—UPVC
Pore Size0.1‑0.22 μm0.1‑0.22 μm
Unit Membrane Area1.0 / 1.5 m²100 / 150 m² (customisable)
Operating Pressure0.01‑0.05 MPa0.01‑0.05 MPa
Operating Temperature5‑45 ℃5‑45 ℃
pH Range2‑10 (1‑12 for chemical‑cleaning mode)2‑10 (1‑12 for chemical‑cleaning mode)
Design Permeate Flux6‑18 L/m²·h6‑18 L/m²·h
Service Life3‑5 years3‑5 years

Core Benefits

  • Superior Fouling Resistance

Flat‑sheet geometry effectively mitigates membrane surface clogging, ideal for water with high suspended‑solid content.

  • Modular Cassette Design

UPVC‑framed cassettes enable fast on‑site installation, well‑suited for rapid deployment in large‑scale projects.

  • Easy‑access Maintenance

Single elements can be replaced independently; complete cassettes can be assembled or disassembled as whole units with extended cleaning intervals.

  • Excellent Permeate Quality

Effluent turbidity <1 NTU

100 % suspended‑solid removal

99.999 % microorganism rejection rate

  • Engineered Customisation

Custom‑tailored membrane area, cassette dimensions and assembly quantities to satisfy diverse project specifications.

Process Advantages — Why Choose Flat‑Sheet MBR System?

  • Excellent fouling tolerance for high‑suspended‑solid wastewater
  • Stable effluent quality, directly applicable for water‑reuse loops
  • Modular layout for streamlined installation and servicing
  • Low operating cost with long service lifespan
  • Flexible combination options for different treatment capacities
  • Can be integrated with curtain‑type or column‑curtain MBR modules to build hybrid MBR systems

FAQ

Q:What is the difference between flat‑sheet membrane elements and flat‑sheet membrane cassettes?
A:An element refers to a single standalone membrane sheet. A cassette is a modular membrane box assembled from multiple individual membrane elements.

Q:What kinds of projects fit flat‑sheet MBR systems?
A:It is recommended for wastewater with high suspended solids and heavy fouling loads, as well as large‑size municipal and industrial wastewater‑treatment works.

Q:Can flat‑sheet MBR systems be used for small‑scale projects?
A:This solution is optimised for large‑scale installations. Curtain‑type or column‑curtain MBR modules are preferred for smaller projects.

Q:Are custom configurations supported?
A:Yes. Customisation is available for membrane area, cassette dimensions and assembly quantities.

Q:What is the expected service life?
A:Typical service life reaches 3‑5 years under standard operating conditions.

Need Custom‑Tailored Solutions?

We provide technical support, product selection guidance and fast quotation services.