Diffused‑Flow Aerators
Even air dispersion · High‑efficiency oxygenation · Energy‑saving & durable performance
Diffused‑flow aerators are high‑performance aeration units built with fine‑pore membrane elements and uniform air‑distribution structures. Even gas dispersion across the membrane produces fine bubbles, delivering stable oxygen transfer and energy‑efficient operation. They are widely used for municipal sewage, biochemical tanks, oxidation ditches, SBR, MBR and many other biological wastewater‑treatment workflows.
Compared with conventional aerators, diffused‑flow aerators offer notable strengths including well‑distributed bubbles, high oxygen‑utilisation and straightforward maintenance.
Product Models
| Model Category | Construction Style | Dimension (mm) | Material | Connection Type | Typical Application |
|---|---|---|---|---|---|
| Standard Diffused‑Flow Aerator | Fine‑pore membrane‑disc design | Φ215 / Φ260 | EPDM, Silicone | Threaded | Municipal sewage, biochemical tanks |
| High‑efficiency Energy‑saving Diffused‑Flow Aerator | Dual‑layer air‑diffusion structure | Φ260 | EPDM, PTFE | Quick‑connect | Industrial wastewater, oxidation ditches |
| Corrosion‑resistant Diffused‑Flow Aerator | Anti‑corrosion coated construction | Φ215 | PTFE, PVC | Threaded | Chemical, electroplating and pharmaceutical wastewater |
| Deep‑water Diffused‑Flow Aerator | Reinforced support assembly | Φ260 | EPDM, PTFE | Flanged | Deep‑water tanks, aeration towers |
Structural Features
Bubble diameter ranges from 1‑3 mm with even distribution for high oxygen‑utilisation efficiency.
Self‑opening‑closing membrane slits prevent sludge accumulation and pore blockage.
Low‑resistance internal geometry cuts blower power consumption.
EPDM or PTFE membrane materials provide reliable acid‑alkali tolerance and anti‑ageing performance.
Modular assembly allows fast disassembly and convenient membrane replacement.
Performance Specifications
| Item | Specification |
|---|---|
| Aerator Dimensions | Φ215 / Φ260 |
| Operating Air Flow | 1.5‑6 m³/h |
| Oxygen Utilisation Efficiency | 30‑45 % |
| Aeration Head Loss | 150‑250 mmH₂O |
| Bubble Diameter | 1‑3 mm |
| Material | EPDM, PTFE, PVC |
| Mounting Type | Fixed / Retractable lift‑out |
| Applicable Water Depth | 2.5‑6.0 m |
| Service Life | 5‑8 years (subject to operating conditions) |
Product Advantages
Selection Guide
| Selection Factor | Available Options | Description | Recommended Use‑case |
|---|---|---|---|
| Construction Type | Single‑layer membrane | Uniform bubble output for shallower tanks | Municipal sewage, biochemical tanks |
| Dual‑layer air‑diffusion | Intensive gas‑liquid mixing for deep‑water conditions | Industrial wastewater, oxidation ditches | |
| Material Options | EPDM | Cost‑effective for general‑purpose municipal wastewater | Municipal wastewater treatment plants |
| PTFE | High corrosion‑resistance and high‑temperature tolerance | Chemical & electroplating wastewater | |
| Mounting Connection | Threaded | Simple installation and servicing | Municipal wastewater treatment plants |
| Flanged | Robust stable connection for deep‑water service | Industrial‑wastewater treatment systems |
CONTACT US | REQUEST A QUOTE
Similar Products
Related Products
FAQ
Q: What are the differences between diffused‑flow aerators and disc fine‑bubble aerators?
A: Diffused‑flow aerators adopt specialised fine‑pore‑membrane geometry to produce more homogeneous bubbles and higher oxygen‑transfer performance. Conventional disc aerators work well in shallow tanks, while diffused‑flow aerators are better suited for deep‑water and high‑loading biological systems.
Q: Are the membrane elements prone to ageing?
A: EPDM and PTFE materials feature excellent anti‑ageing properties, delivering 5‑8‑year service life under normal operating conditions.
Q: Can custom connection fittings be supplied?
A: Yes. Threaded, quick‑connect and flanged interfaces can be custom‑tailored according to pipe diameter, airflow and mounting requirements.
Q: Are diffused‑flow aerators suitable for high‑temperature or acid‑alkali environments?
A: Yes. PTFE‑grade versions withstand temperatures up to 120 °C and offer outstanding acid‑alkali resistance.
Q: Can diffused‑flow aerators maintain even air output under low‑air‑flow conditions?
A: Yes. Thanks to self‑opening‑closing membrane slits, they maintain uniform bubble dispersion without biased flow or oversized bubbles even at reduced airflow rates.
Q: Are diffused‑flow aerators suitable for intermittent‑aeration and SBR processes?
A: Highly suitable. Self‑regulating membrane slits deliver stable performance under cyclic / intermittent aeration and SBR working cycles, without premature membrane fatigue or damage from frequent start‑stop cycles.
Q: What is the recommended replacement cycle for diffused‑flow aerator membranes?
A: EPDM membranes last 5‑8 years under normal service; PTFE membranes achieve 8‑10 years. Replace membranes if uneven bubbling, rising head loss or obvious material ageing occurs.
Q: Are diffused‑flow aerators recommended for high‑viscosity or oil‑bearing wastewater?
A: Application scope is limited. These aerators are optimised for standard municipal sewage and common‑grade industrial wastewater.
Need Custom‑Tailored Solutions?
We provide technical support, product selection guidance and fast quotation services.